Post Posted: Thu Nov 14, 2013 12:29 pm Reply with quote    Back to top    

DataStage® Release: 8x
Job Type: Parallel
OS: Windows
Need RCP enable, Wanted to know if there is a way to avoid warnings in connector stage

JOB design: SF -->Transformer -->Connector stage
I am going to use this as a multi instance job to load different DB2 tables so have to use RCP.

Sequential file (which is using schema files for metadata with RCP enabled --> transformer (to add a TS Field) --> connector stage.
I have searched previous post for similar warnings and have seen suggestions to Disable RCP but in my situation I need RCP and am trying to avoid warring’s.

Warning: Schema field in input data set 0 not present in design time information. Extended field properties for this field will not be available

Thanks in advance
ray.wurlod

Premium Poster
Participant

Group memberships:
Premium Members, Inner Circle, Australia Usergroup, Server to Parallel Transition Group

Joined: 23 Oct 2002
Posts: 54541
Location: Sydney, Australia
Points: 295742

Post Posted: Thu Nov 14, 2013 2:27 pm Reply with quote    Back to top    

You could use a message handler to demote the warnings to informational messages. Or you could investigate which fields are missing, and either modify the schema file or the data to make sure that th ...

_________________
IBM Software Services Group
Any contribution to this forum is my own opinion and does not necessarily reflect any position that IBM may hold.
Rate this response:  
Not yet rated
sudha.gundap



Group memberships:
Premium Members

Joined: 14 Jul 2011
Posts: 7
Location: NJ
Points: 75

Post Posted: Thu Nov 14, 2013 2:44 pm Reply with quote    Back to top    

Thanks for the response Ray.
I am able to load data into all tables with no issues.
But, Both(schema File and DB2 Table) have same fields and I am receiving same Warning for all the fields.
It would be of great help if we have a way other than message handler.
Rate this response:  
Not yet rated
TonyInFrance



Group memberships:
Premium Members

Joined: 27 May 2008
Posts: 287
Location: Paris
Points: 3455

Post Posted: Wed Mar 04, 2015 5:45 am Reply with quote    Back to top    

I have this same issue.
I need to use RCP since I'm using a generic job and thus my transformer has certain columns defined, i.e. those that I'm programming specifically. Over and above, I need to copy the columns present in the dataset and thus I select RCP.

I get warnings for the columns not defined explicitly.

Isn't it possible to eradicate these without message handlers?

Thanks

Tony

_________________
Tony
BI Consultant - Datastage
Rate this response:  
Not yet rated
Thomas.B
Participant



Joined: 09 Apr 2015
Posts: 62
Location: France - Nantes
Points: 409

Post Posted: Wed Oct 23, 2019 8:50 am Reply with quote    Back to top    

4 years later, sorry for the grave digging Smile

I had the exact same issue. To solve it, I had to add a "copy" stage right before the database connector, enable RCP and delete all the output columns.

_________________
BI Consultant
DSXConsult
Rate this response:  
Display posts from previous:       

Add To Favorites
View next topic
View previous topic
You cannot post new topics in this forum
You cannot reply to topics in this forum
You cannot edit your posts in this forum
You cannot delete your posts in this forum
You cannot vote in polls in this forum



Powered by phpBB © 2001, 2002 phpBB Group
Theme & Graphics by Daz :: Portal by Smartor
All times are GMT - 6 Hours