Hi Michael,
I don't think there is a technique to convert the params into parameter set, I'm sure you aware of this
just copu the DSParam file from old version to new version and they crete a parameter set with the existing params,
please let me know if you need more information on this.
Search found 54 matches
- Mon May 07, 2012 9:02 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Tool / Technique to convert Connectors to use Parameter Set
- Replies: 4
- Views: 1981
- Mon May 07, 2012 4:37 am
- Forum: General
- Topic: Generating a job report via DataSTage client GUI
- Replies: 5
- Views: 8536
- Thu Mar 08, 2012 7:15 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: The OCI function OraOCIEnvNlsCreate:OCI_UTF16ID
- Replies: 1
- Views: 3250
The OCI function OraOCIEnvNlsCreate:OCI_UTF16ID
Hi All, I'm getting a error "The OCI function OraOCIEnvNlsCreate:OCI_UTF16ID" and I got a resolution from the following links http://www.dsxchange.com/viewtopic.php?t=137569&highlight=he+OCI+function+OraOCIEnvNlsCreate%3AOCI_UTF16ID and http://www-01.ibm.com/support/docview.wss?uid=swg...
- Mon Feb 13, 2012 3:16 am
- Forum: IBM<sup>®</sup> SOA Editions (Formerly RTI Services)
- Topic: Web Service Error
- Replies: 4
- Views: 7121
- Wed Oct 12, 2011 6:10 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: APT_Locator Fatal Error
- Replies: 2
- Views: 2633
- Wed Oct 12, 2011 5:53 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Job Aborted, but still showing as running in Director.
- Replies: 7
- Views: 4573
alternate solution, just rename the job, You'll be out of th
the suggestion is the perfect solution for this but if you are not a administrator then for instant you can solve this problem
the alternate solution, just rename the job, You'll be out of this problem
the alternate solution, just rename the job, You'll be out of this problem
- Thu Aug 11, 2011 3:46 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: To trim leading zero's in a sequential file
- Replies: 10
- Views: 8482
To trim leading zero's in a sequential file
go to file properties in the target file and set the column/field properties and its values
- Fri Jun 24, 2011 7:10 am
- Forum: General
- Topic: DS 7.5 and 8.1 on same server.
- Replies: 10
- Views: 3843
Yes It is possible
Yep Rohit, It is possible to install 7.5 and 8.1 versions on a same server/system, but it is not possible to work on both versions parallel, when U install 8 Version on which 7.5 is already installed you'll get a Multi-Client Manager tool to switch between the versions, so you can work on any one ve...
- Thu Dec 16, 2010 10:41 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Data Stage 8.0 giving problem while running
- Replies: 2
- Views: 1476
Data Stage 8.0 giving problem while running
Hi, I installed data stage 8.0 on my PC (wondows based, windows server 2003) and worked fine a couple of days, since yesterday it is giving me problem, when I run the job, it is giving the following message a million times " Attempting to Cleanup after ABORT raised in job merger ." hear me...
- Mon Apr 05, 2010 8:04 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: ZIP files using Execute command stage
- Replies: 11
- Views: 5727
- Mon Apr 05, 2010 7:53 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: restart sequence from checkpoint without aborting other job
- Replies: 28
- Views: 18860
- Wed Mar 24, 2010 5:29 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Surrogate key generator
- Replies: 5
- Views: 3948
sarogate Key
Yes that is Right, and if you want to generate with a increment of 1 then use the following as a stage varible in transformar "0 + @INROWNUM +(mod(@PARTITIONNUM,@NUMPARTITIONS)) + ((@INROWNUM-1) * (@NUMPARTITIONS-1))"
- Wed Mar 24, 2010 4:27 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Why Modify stage is used when Transformer can do
- Replies: 7
- Views: 3505
Why Modify stage is used when Transformer can do
when we can drop/modify column and do null Handling using Transformer, what are the other(or unique) uses of a Modify stage, please let me know, thank you.
- Thu Mar 11, 2010 1:43 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Job Aborting due to APT_CombinedOperatorCOntroller Error
- Replies: 6
- Views: 5089
- Thu Jan 21, 2010 4:34 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Left Zero fill, force to field length
- Replies: 11
- Views: 7288