Search found 54 matches

by ulab
Mon May 07, 2012 9:02 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Tool / Technique to convert Connectors to use Parameter Set
Replies: 4
Views: 1981

Hi Michael,

I don't think there is a technique to convert the params into parameter set, I'm sure you aware of this

just copu the DSParam file from old version to new version and they crete a parameter set with the existing params,

please let me know if you need more information on this.
by ulab
Mon May 07, 2012 4:37 am
Forum: General
Topic: Generating a job report via DataSTage client GUI
Replies: 5
Views: 8536

is this problem resolved? please let me know if the above suggestions worked out? I'm also facing the same issue
by ulab
Thu Mar 08, 2012 7:15 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: The OCI function OraOCIEnvNlsCreate:OCI_UTF16ID
Replies: 1
Views: 3250

The OCI function OraOCIEnvNlsCreate:OCI_UTF16ID

Hi All, I'm getting a error "The OCI function OraOCIEnvNlsCreate:OCI_UTF16ID" and I got a resolution from the following links http://www.dsxchange.com/viewtopic.php?t=137569&highlight=he+OCI+function+OraOCIEnvNlsCreate%3AOCI_UTF16ID and http://www-01.ibm.com/support/docview.wss?uid=swg...
by ulab
Mon Feb 13, 2012 3:16 am
Forum: IBM<sup>®</sup> SOA Editions (Formerly RTI Services)
Topic: Web Service Error
Replies: 4
Views: 7121

Is it solved if not anybody please answer it
by ulab
Wed Oct 12, 2011 5:53 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Job Aborted, but still showing as running in Director.
Replies: 7
Views: 4573

alternate solution, just rename the job, You'll be out of th

the suggestion is the perfect solution for this but if you are not a administrator then for instant you can solve this problem
the alternate solution, just rename the job, You'll be out of this problem
by ulab
Thu Aug 11, 2011 3:46 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: To trim leading zero's in a sequential file
Replies: 10
Views: 8482

To trim leading zero's in a sequential file

go to file properties in the target file and set the column/field properties and its values
by ulab
Fri Jun 24, 2011 7:10 am
Forum: General
Topic: DS 7.5 and 8.1 on same server.
Replies: 10
Views: 3843

Yes It is possible

Yep Rohit, It is possible to install 7.5 and 8.1 versions on a same server/system, but it is not possible to work on both versions parallel, when U install 8 Version on which 7.5 is already installed you'll get a Multi-Client Manager tool to switch between the versions, so you can work on any one ve...
by ulab
Thu Dec 16, 2010 10:41 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Data Stage 8.0 giving problem while running
Replies: 2
Views: 1476

Data Stage 8.0 giving problem while running

Hi, I installed data stage 8.0 on my PC (wondows based, windows server 2003) and worked fine a couple of days, since yesterday it is giving me problem, when I run the job, it is giving the following message a million times " Attempting to Cleanup after ABORT raised in job merger ." hear me...
by ulab
Mon Apr 05, 2010 8:04 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: ZIP files using Execute command stage
Replies: 11
Views: 5727

I suggest you try gzip command, it will work fine instead of zip in Unix/linux
by ulab
Mon Apr 05, 2010 7:53 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: restart sequence from checkpoint without aborting other job
Replies: 28
Views: 18860

is it a single sequencer that running a and d jobs above?
by ulab
Wed Mar 24, 2010 5:29 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Surrogate key generator
Replies: 5
Views: 3948

sarogate Key

Yes that is Right, and if you want to generate with a increment of 1 then use the following as a stage varible in transformar "0 + @INROWNUM +(mod(@PARTITIONNUM,@NUMPARTITIONS)) + ((@INROWNUM-1) * (@NUMPARTITIONS-1))"
by ulab
Wed Mar 24, 2010 4:27 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Why Modify stage is used when Transformer can do
Replies: 7
Views: 3505

Why Modify stage is used when Transformer can do

when we can drop/modify column and do null Handling using Transformer, what are the other(or unique) uses of a Modify stage, please let me know, thank you.
by ulab
Thu Mar 11, 2010 1:43 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Job Aborting due to APT_CombinedOperatorCOntroller Error
Replies: 6
Views: 5089

No Answer for this..........Incomplete post will make the new user disoppoint
by ulab
Thu Jan 21, 2010 4:34 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Left Zero fill, force to field length
Replies: 11
Views: 7288

chulett wrote:Then perhaps Right('000000000000':Trim(In.AD-ACCT-ID),12) would work. ...
thanks to all for their time, the problem got resolved with the following logic in the source stage(Oracle DB)

LPAD(supl.uniquename,12,'0') as uniquename

Once again thanks to All :)